One off Housing Wastewater Summary
The potential suitability of a site for the development of an on-site system is assessed using the methodology outlined in Wastewater Treatment Manual: Treatment Systems for Single Houses (EPA, 2000). The groundwater protection responses set out below should be used during the desk study assessment of a site to give an early indication of the suitability of a site for an on-site system. Information from the on-site assessment should be used to confirm or modify the response.
Response Matrix for On-site Treatment Systems
CLICK ON THE IMAGE TO VIEW A LARGER VERSION IN ANOTHER WINDOW
* For public, group scheme or industrial water supply sources where protection zones have not been delineated, the arbitrary distances given in DELG/EPA/GSI (1999) of 300 m for the Inner Protection Area (SI) and 1000 m for the Outer Protection Area (SO) should be used as a guide up-gradient of the source.
| R1 |
Acceptable subject to normal good practice (i.e. system selection, construction, operation and maintenance in accordance with EPA (2000)). |
| R2¹ |
Acceptable subject to normal good practice. Where domestic water supplies are located nearby, particular attention should be given to the depth of subsoil over bedrock such that the minimum depths required (EPA, 2000) are met and that the likelihood of microbial pollution is minimised. |
| R2² |
Acceptable subject to normal good practice and the following additional condition: 1) There is a minimum thickness of 2 m unsaturated soil/subsoil beneath the invert of the percolation trench of a conventional septic tank system; OR 1) A treatment system other than a conventional septic tank system as described in EPA (2000) is installed, with a minimum thickness of 0.6 m unsaturated soil/subsoil with P/T values 1 from 1 to 50 (in addition to the polishing filter which should be a minimum depth of 0.6 m), beneath the invert of the polishing filter (i.e. 1.2 m in total for a soil polishing filter). |
| R2³ |
Acceptable subject to normal good practice, condition 1 above and the following additional condition: 2) The authority must be satisfied that, on the evidence of the groundwater quality of the source and the number of existing houses, the accumulation of significant nitrate and/or microbiological contamination is unlikely. |
| R24 |
Acceptable subject to normal good practice, conditions 1 and 2 above and the following additional condition: 3) No on-site treatment system should be located within 60 m of the public, group scheme or industrial water supply source. |
| R3¹ |
Not generally acceptable, unless: A conventional septic tank system is installed with a minimum thickness of 2 m unsaturated soil/subsoil beneath the invert of the percolation trench (i.e. an increase of 0.8 m from the EPA manual); OR A treatment system other than a conventional septic tank system, as described in EPA (2000), is installed with a minimum thickness of 0.6 m unsaturated soil/subsoil with P/T values from 1 to 50 (in addition to the polishing filter which should be a minimum depth of 0.6 m), beneath the invert of the polishing filter (i.e. 1.2m in total for a soil polishing filter); AND subject to the following conditions: 1)The authority must be satisfied that, on the evidence of the groundwater quality of the source and the number of existing houses, the accumulation of significant nitrate and/or microbiological contamination is unlikely. 2)No on-site treatment system should be located within 60 m of the public, group scheme or industrial water supply source. 3) A management and maintenance agreement is completed with the systems supplier. |
| R3² |
Not generally acceptable unless: A treatment system other than a conventional septic tank system, as described in EPA (2000), is installed with a minimum thickness of 1.2 m unsaturated soil/subsoil with P/T values from 1 to 50, (in addition to the polishing filter which should be a minimum depth of 0.6 m) beneath the invert of the polishing filter (i.e. 1.8m in total for a soil polishing filter); AND subject to the following conditions: 1)The authority must be satisfied that, on the evidence of the groundwater quality of the source and the number of existing houses, the accumulation of significant nitrate and/or microbiological contamination is unlikely. 2) No on-site treatment system should be located within 60 m of the public, group scheme or industrial water supply source. 3) A management and maintenance agreement is completed with the systems supplier. |
¹ The T value (expressed as min/25mm) is the time taken for the water level to drop a specified distance in a percolation test hole. For shallow subsoils the test hole requirements are different and hence the test results are called P values. For further advice see page 25 of the EPA Manual (2000).